dc.contributor.author |
De Vreede, JPM
|
en_US |
dc.contributor.author |
Korfage, W
|
en_US |
dc.contributor.author |
Persson, P
|
en_US |
dc.contributor.author |
Brunetti, L
|
en_US |
dc.contributor.author |
Lopez, V
|
en_US |
dc.contributor.author |
Petras, I
|
en_US |
dc.contributor.author |
Morard, P
|
en_US |
dc.contributor.author |
Hejsek, F
|
en_US |
dc.contributor.author |
Torok, A
|
en_US |
dc.contributor.author |
Ruhaak, J
|
en_US |
dc.contributor.author |
Ascroft, J
|
en_US |
dc.contributor.author |
Dressler, E
|
en_US |
dc.contributor.author |
Celep, M
|
en_US |
dc.contributor.author |
Lapuh, R
|
en_US |
dc.contributor.author |
Achkar, J
|
en_US |
dc.date.accessioned |
2007-02-08T08:38:52Z |
en_US |
dc.date.accessioned |
2007-06-07T10:08:43Z |
|
dc.date.available |
2007-02-08T08:38:52Z |
en_US |
dc.date.available |
2007-06-07T10:08:43Z |
|
dc.date.copyright |
|
en_US |
dc.date.issued |
2001-04 |
en_US |
dc.identifier.citation |
De Vreede, JPM, et al. 2001. International comparison for RF power in the frequency range up to 18 GHz. IEEE Transactions on Instrumentation and Measurement, vol. 50(2), pp 409-413. |
en_US |
dc.identifier.issn |
0018-9456 |
en_US |
dc.identifier.uri |
http://hdl.handle.net/10204/1671
|
en_US |
dc.identifier.uri |
http://hdl.handle.net/10204/1671
|
|
dc.description.abstract |
A Euromet international laboratory comparison (Project 393) has been carried out between 14 national standards laboratories. Thermistor mounts were used, equipped with PC7 as well as Type N connectors. The comparison is carried out using the normal equipment of the laboratory for high-quality external calibration. The results show good agreement in measuring the calibration coefficient of the thermistor mounts within the claimed expanded uncertainty (typically between 1% and 2%). It confirms the equivalence of national standards for RF power up to 18 GHz. In one case, corrective action is proposed. |
en_US |
dc.format.extent |
102090 bytes |
en_US |
dc.format.mimetype |
application/pdf |
en_US |
dc.language.iso |
en |
en_US |
dc.publisher |
Institute of Electrical and Electronics Engineers Inc. |
en_US |
dc.rights |
Copyright: 2001 Institute of Electrical and Electronics Engineers Inc. |
en_US |
dc.source |
|
en_US |
dc.subject |
Engineering |
en_US |
dc.subject |
Equivalence of standards |
en_US |
dc.subject |
Measurement standards |
en_US |
dc.subject |
Power measurements |
en_US |
dc.subject |
Thermistors |
en_US |
dc.subject |
Transfer standards |
en_US |
dc.title |
International comparison for RF power in the frequency range up to 18 GHz |
en_US |
dc.type |
Article |
en_US |
dc.identifier.apacitation |
De Vreede, J., Korfage, W., Persson, P., Brunetti, L., Lopez, V., Petras, I., ... Achkar, J. (2001). International comparison for RF power in the frequency range up to 18 GHz. http://hdl.handle.net/10204/1671 |
en_ZA |
dc.identifier.chicagocitation |
De Vreede, JPM, W Korfage, P Persson, L Brunetti, V Lopez, I Petras, P Morard, et al "International comparison for RF power in the frequency range up to 18 GHz." (2001) http://hdl.handle.net/10204/1671 |
en_ZA |
dc.identifier.vancouvercitation |
De Vreede J, Korfage W, Persson P, Brunetti L, Lopez V, Petras I, et al. International comparison for RF power in the frequency range up to 18 GHz. 2001; http://hdl.handle.net/10204/1671. |
en_ZA |
dc.identifier.ris |
TY - Article
AU - De Vreede, JPM
AU - Korfage, W
AU - Persson, P
AU - Brunetti, L
AU - Lopez, V
AU - Petras, I
AU - Morard, P
AU - Hejsek, F
AU - Torok, A
AU - Ruhaak, J
AU - Ascroft, J
AU - Dressler, E
AU - Celep, M
AU - Lapuh, R
AU - Achkar, J
AB - A Euromet international laboratory comparison (Project 393) has been carried out between 14 national standards laboratories. Thermistor mounts were used, equipped with PC7 as well as Type N connectors. The comparison is carried out using the normal equipment of the laboratory for high-quality external calibration. The results show good agreement in measuring the calibration coefficient of the thermistor mounts within the claimed expanded uncertainty (typically between 1% and 2%). It confirms the equivalence of national standards for RF power up to 18 GHz. In one case, corrective action is proposed.
DA - 2001-04
DB - ResearchSpace
DP - CSIR
KW - Engineering
KW - Equivalence of standards
KW - Measurement standards
KW - Power measurements
KW - Thermistors
KW - Transfer standards
LK - https://researchspace.csir.co.za
PY - 2001
SM - 0018-9456
T1 - International comparison for RF power in the frequency range up to 18 GHz
TI - International comparison for RF power in the frequency range up to 18 GHz
UR - http://hdl.handle.net/10204/1671
ER -
|
en_ZA |