dc.identifier.citation Veldman, CS. 2003. Novel implementation of an ISO standard method for primary vibration calibration by laser interferometry. Metrologia, vol. 40(2), pp 1-8 en
dc.identifier.issn 0026-1394
dc.identifier.uri http://hdl.handle.net/10204/739
dc.description Copyright: 2003 BIPM and IOP Publishing Ltd en
dc.description.abstract An implementation of the sine-approximation method of ISO 16063-11 (primary vibration calibration by laser interferometry) is described. The quadrature interference signals are generated using an interferometer as described in method 3 of ISO 16063-11. The signal processing required for the successful implementation of this method of ISO 16063-11 has been implemented by various metrology institutes using various techniques. For the implementation of these techniques, different hardware and software configurations are used, ranging from expensive VAX computer systems to digital storage oscilloscopes. A novel, cost effective, PC based system has been developed and is described herein. The hardware consists of a Pentium 200 with 256 MB of RAM. A commercial, four-channel analogue to digital (A to D) conversion card is used for performing the data capturing, while the signal processing software was developed to run under Microsoft Windows The system was evaluated using data signals with and without disturbances added. The data signals were generated using software techniques. Further system validation was achieved using experimental data. en
dc.language.iso en en
dc.publisher BIPM and IOP Publishing Ltd en
dc.subject ISO standard methods en
dc.subject Sine-approximation methods en
dc.subject Quadrature interference en
dc.subject Primary vibration Calibration en
dc.title Novel implementation of an ISO standard method for primary vibration calibration by laser interferometry en
dc.type Article en
dc.identifier.apacitation Veldman, C. (2003). Novel implementation of an ISO standard method for primary vibration calibration by laser interferometry. http://hdl.handle.net/10204/739 en_ZA
dc.identifier.chicagocitation Veldman, CS "Novel implementation of an ISO standard method for primary vibration calibration by laser interferometry." (2003) http://hdl.handle.net/10204/739 en_ZA
dc.identifier.vancouvercitation Veldman C. Novel implementation of an ISO standard method for primary vibration calibration by laser interferometry. 2003; http://hdl.handle.net/10204/739. en_ZA
dc.identifier.ris TY - Article AU - Veldman, CS AB - An implementation of the sine-approximation method of ISO 16063-11 (primary vibration calibration by laser interferometry) is described. The quadrature interference signals are generated using an interferometer as described in method 3 of ISO 16063-11. The signal processing required for the successful implementation of this method of ISO 16063-11 has been implemented by various metrology institutes using various techniques. For the implementation of these techniques, different hardware and software configurations are used, ranging from expensive VAX computer systems to digital storage oscilloscopes. A novel, cost effective, PC based system has been developed and is described herein. The hardware consists of a Pentium 200 with 256 MB of RAM. A commercial, four-channel analogue to digital (A to D) conversion card is used for performing the data capturing, while the signal processing software was developed to run under Microsoft Windows The system was evaluated using data signals with and without disturbances added. The data signals were generated using software techniques. Further system validation was achieved using experimental data. DA - 2003 DB - ResearchSpace DP - CSIR KW - ISO standard methods KW - Sine-approximation methods KW - Quadrature interference KW - Primary vibration Calibration LK - https://researchspace.csir.co.za PY - 2003 SM - 0026-1394 T1 - Novel implementation of an ISO standard method for primary vibration calibration by laser interferometry TI - Novel implementation of an ISO standard method for primary vibration calibration by laser interferometry UR - http://hdl.handle.net/10204/739 ER - en_ZA