ResearchSpace

Comparison of the heat treatment response of wrought and SSM-HPDC alloy 6082

Show simple item record

dc.contributor.author Möller, H
dc.contributor.author Govender, G
dc.contributor.author Stumpf, WE
dc.date.accessioned 2011-07-01T07:25:29Z
dc.date.available 2011-07-01T07:25:29Z
dc.date.issued 2011-06
dc.identifier.citation Möller, H, Govender, G, and Stumpf, WE. 2011. Comparison of the heat treatment response of wrought and SSM-HPDC alloy 6082. 5th International Light Metals Technology Conference 2011 (LMT), Lüneburg, Germany, 19-22 July 2011, 690, pp 242-245 en_US
dc.identifier.isbn 978-3-03785-180-7
dc.identifier.issn 1662-9752
dc.identifier.issn 0255-5476
dc.identifier.uri http://www.scientific.net/MSF.690.242
dc.identifier.uri http://hdl.handle.net/10204/5078
dc.description 5th International Light Metals Technology Conference 2011 (LMT), Lüneburg, Germany, 19-22 July 2011 en_US
dc.description.abstract The natural and artificial aging responses of wrought and SSM-HPDC alloy 6082 are compared. It is shown that the heat treatment response of this Al-Mg-Si alloy is not influenced by differences in microstructures produced by different processing routes. Wrought alloy 6082 is known to experience an unfavourable effect of prior natural aging on the subsequent artificial aging response, which was also found for SSM-HPDC 6082 in this study. The tensile properties of SSMHPDC 6082-T6 agree well with those specified for wrought 6082-T6, except for a much lower ductility of the SSM-HPDC variant. en_US
dc.language.iso en en_US
dc.publisher Trans Tec Publications en_US
dc.relation.ispartofseries Workflow;6712
dc.subject Al-Mg-Si alloys en_US
dc.subject Rheocasting en_US
dc.subject Heat treatment en_US
dc.subject Aging en_US
dc.title Comparison of the heat treatment response of wrought and SSM-HPDC alloy 6082 en_US
dc.type Conference Presentation en_US
dc.identifier.apacitation Möller, H., Govender, G., & Stumpf, W. (2011). Comparison of the heat treatment response of wrought and SSM-HPDC alloy 6082. Trans Tec Publications. http://hdl.handle.net/10204/5078 en_ZA
dc.identifier.chicagocitation Möller, H, G Govender, and WE Stumpf. "Comparison of the heat treatment response of wrought and SSM-HPDC alloy 6082." (2011): http://hdl.handle.net/10204/5078 en_ZA
dc.identifier.vancouvercitation Möller H, Govender G, Stumpf W, Comparison of the heat treatment response of wrought and SSM-HPDC alloy 6082; Trans Tec Publications; 2011. http://hdl.handle.net/10204/5078 . en_ZA
dc.identifier.ris TY - Conference Presentation AU - Möller, H AU - Govender, G AU - Stumpf, WE AB - The natural and artificial aging responses of wrought and SSM-HPDC alloy 6082 are compared. It is shown that the heat treatment response of this Al-Mg-Si alloy is not influenced by differences in microstructures produced by different processing routes. Wrought alloy 6082 is known to experience an unfavourable effect of prior natural aging on the subsequent artificial aging response, which was also found for SSM-HPDC 6082 in this study. The tensile properties of SSMHPDC 6082-T6 agree well with those specified for wrought 6082-T6, except for a much lower ductility of the SSM-HPDC variant. DA - 2011-06 DB - ResearchSpace DP - CSIR KW - Al-Mg-Si alloys KW - Rheocasting KW - Heat treatment KW - Aging LK - https://researchspace.csir.co.za PY - 2011 SM - 978-3-03785-180-7 SM - 1662-9752 SM - 0255-5476 T1 - Comparison of the heat treatment response of wrought and SSM-HPDC alloy 6082 TI - Comparison of the heat treatment response of wrought and SSM-HPDC alloy 6082 UR - http://hdl.handle.net/10204/5078 ER - en_ZA


Files in this item

This item appears in the following Collection(s)

Show simple item record