ResearchSpace

Factors influencing the detection of unsafe hangingwall conditions.

Show simple item record

dc.contributor.author Peake, AV
dc.contributor.author Ashworth, SGE
dc.date.accessioned 2007-11-22T07:20:19Z
dc.date.available 2007-11-22T07:20:19Z
dc.date.issued 1996-10
dc.identifier.citation Peake, AV and Ashworth, SGE. 1996 . Factors influencing the detection of unsafe hangingwall conditions. Safety in Mines Research Advisory Committee, GAP 202, October, 1996, pp 1-67 en
dc.identifier.uri http://hdl.handle.net/10204/1691
dc.description.abstract This project reports on the findings of an investigation into reasons why hanging wall examination procedures fail to prevent fall of ground accidents on gold and platinum mines. Ideally, these procedures should identify every unsafe hanging wall condition and ensure that appropriate action is taken to remedy each unsafe condition. en
dc.language.iso en en
dc.subject SIMRAC en
dc.subject GAP 202 en
dc.subject Hangingwall conditions en
dc.subject Accidents en
dc.subject Mines en
dc.title Factors influencing the detection of unsafe hangingwall conditions. en
dc.type Conference Presentation en
dc.identifier.apacitation Peake, A., & Ashworth, S. (1996). Factors influencing the detection of unsafe hangingwall conditions. http://hdl.handle.net/10204/1691 en_ZA
dc.identifier.chicagocitation Peake, AV, and SGE Ashworth. "Factors influencing the detection of unsafe hangingwall conditions." (1996): http://hdl.handle.net/10204/1691 en_ZA
dc.identifier.vancouvercitation Peake A, Ashworth S, Factors influencing the detection of unsafe hangingwall conditions; 1996. http://hdl.handle.net/10204/1691 . en_ZA
dc.identifier.ris TY - Conference Presentation AU - Peake, AV AU - Ashworth, SGE AB - This project reports on the findings of an investigation into reasons why hanging wall examination procedures fail to prevent fall of ground accidents on gold and platinum mines. Ideally, these procedures should identify every unsafe hanging wall condition and ensure that appropriate action is taken to remedy each unsafe condition. DA - 1996-10 DB - ResearchSpace DP - CSIR KW - SIMRAC KW - GAP 202 KW - Hangingwall conditions KW - Accidents KW - Mines LK - https://researchspace.csir.co.za PY - 1996 T1 - Factors influencing the detection of unsafe hangingwall conditions TI - Factors influencing the detection of unsafe hangingwall conditions UR - http://hdl.handle.net/10204/1691 ER - en_ZA