Maistry, NatteleSchutz, Robert ACox, Ettienne2019-05-072019-05-072018-09Maistry, N., Schutz, R.A. & Cox, E. 2018. The quantification of corona discharges on high voltage electrical equipment in the UV spectrum using a corona camera. In: International Conference on Diagnostics in Electrical Engineering (Diagnostika) CDEE 2018, Pilsen, Czech Republic, 4-7 September 2018978-1-5386-4424-9/DOI: 10.1109/DIAGNOSTIKA.2018.8526024https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=8526024&tag=1http://toc.proceedings.com/41450webtoc.pdfhttp://hdl.handle.net/10204/10973Presented in: International Conference on Diagnostics in Electrical Engineering (Diagnostika) CDEE 2018, Pilsen, Czech Republic, 4-7 September 2018. Due to copyright restrictions, the attached PDF file only contains the abstract of the full-text item. For access to the full-text item, please consult the publisher's website.The current power line fault detection equipment can only locate a fault by detecting corona and heat radiated by the faults. This equipment cannot quantify the ultraviolet (UV) radiation of the fault in radiometric dimensions (W/cm2). The CSIR has developed the first radiometric technology camera platform in both the UV and IR spectrums (“QUVIR”) in order to quantify power line faults. This paper will provide a brief description on the new UV quantification algorithm.enCamerasCoronaHV Power linesImage intensifiersMULTICAMUV quantificationThe quantification of corona discharges on high voltage electrical equipment in the UV spectrum using a corona cameraConference PresentationMaistry, N., Schutz, R. A., & Cox, E. (2018). The quantification of corona discharges on high voltage electrical equipment in the UV spectrum using a corona camera. IEEE. http://hdl.handle.net/10204/10973Maistry, Nattele, Robert A Schutz, and Ettienne Cox. "The quantification of corona discharges on high voltage electrical equipment in the UV spectrum using a corona camera." (2018): http://hdl.handle.net/10204/10973Maistry N, Schutz RA, Cox E, The quantification of corona discharges on high voltage electrical equipment in the UV spectrum using a corona camera; IEEE; 2018. http://hdl.handle.net/10204/10973 .TY - Conference Presentation AU - Maistry, Nattele AU - Schutz, Robert A AU - Cox, Ettienne AB - The current power line fault detection equipment can only locate a fault by detecting corona and heat radiated by the faults. This equipment cannot quantify the ultraviolet (UV) radiation of the fault in radiometric dimensions (W/cm2). The CSIR has developed the first radiometric technology camera platform in both the UV and IR spectrums (“QUVIR”) in order to quantify power line faults. This paper will provide a brief description on the new UV quantification algorithm. DA - 2018-09 DB - ResearchSpace DP - CSIR KW - Cameras KW - Corona KW - HV Power lines KW - Image intensifiers KW - MULTICAM KW - UV quantification LK - https://researchspace.csir.co.za PY - 2018 SM - 978-1-5386-4424-9/ T1 - The quantification of corona discharges on high voltage electrical equipment in the UV spectrum using a corona camera TI - The quantification of corona discharges on high voltage electrical equipment in the UV spectrum using a corona camera UR - http://hdl.handle.net/10204/10973 ER -