Hardman, DRCreedy, DPPhillips, HR2007-10-052007-10-052001-06Hardman, DR, Creedy, DP and Phillips, HR. 2001. Strategies to monitor non-homogeneous atmospheres in sealed off panels in coal mines. Safety in Mines Research Advisory Committee: School of Mining Engineering University of the Witwatersrand, COL 602, June, 2001, pp 1-31http://hdl.handle.net/10204/1284This report is made up of Report summary and main content/articleMany South African coal mines contain large areas sealed off from the mine ventilation. These areas contain an atmosphere sampled only at or near the seals. The research described in this report was commissioned to examine whether the current methods of monitoring sealed off areas are adequate, how South African practice compares with the methods used in other countries and whether alternative monitoring systems exist. The research has shown that monitoring deep into sealed areas is not normally a major concern world-wide and that periphery or near-seal sampling is normal. When circumstances indicate the need for multi-point sampling in sealed areas, the accepted method is the tube bundle system, where samples are drawn through small diameter tubes to a central (usually surface) installation and the atmosphere from each tube is sampled sequentially prior to being analysed for the presence of a range of gases. Although the report identifies a number of factors which increase the risk of the occurrence of non-homogeneous atmospheres in a sealed off area, the one tube bundle installation in South Africa for which data has been analysed has indicated a remarkably uniform atmosphere, where all the sampling points gave readings very similar to standard near-seal observations.enSIMRACNon-homogenous atmosphere monitoringSealed off panelsSouth African coal minesCOL602Strategies to monitor non-homogeneous atmospheres in sealed off panels in coal mines.Conference PresentationHardman, D., Creedy, D., & Phillips, H. (2001). Strategies to monitor non-homogeneous atmospheres in sealed off panels in coal mines. http://hdl.handle.net/10204/1284Hardman, DR, DP Creedy, and HR Phillips. "Strategies to monitor non-homogeneous atmospheres in sealed off panels in coal mines." (2001): http://hdl.handle.net/10204/1284Hardman D, Creedy D, Phillips H, Strategies to monitor non-homogeneous atmospheres in sealed off panels in coal mines; 2001. http://hdl.handle.net/10204/1284 .TY - Conference Presentation AU - Hardman, DR AU - Creedy, DP AU - Phillips, HR AB - Many South African coal mines contain large areas sealed off from the mine ventilation. These areas contain an atmosphere sampled only at or near the seals. The research described in this report was commissioned to examine whether the current methods of monitoring sealed off areas are adequate, how South African practice compares with the methods used in other countries and whether alternative monitoring systems exist. The research has shown that monitoring deep into sealed areas is not normally a major concern world-wide and that periphery or near-seal sampling is normal. When circumstances indicate the need for multi-point sampling in sealed areas, the accepted method is the tube bundle system, where samples are drawn through small diameter tubes to a central (usually surface) installation and the atmosphere from each tube is sampled sequentially prior to being analysed for the presence of a range of gases. Although the report identifies a number of factors which increase the risk of the occurrence of non-homogeneous atmospheres in a sealed off area, the one tube bundle installation in South Africa for which data has been analysed has indicated a remarkably uniform atmosphere, where all the sampling points gave readings very similar to standard near-seal observations. DA - 2001-06 DB - ResearchSpace DP - CSIR KW - SIMRAC KW - Non-homogenous atmosphere monitoring KW - Sealed off panels KW - South African coal mines KW - COL602 LK - https://researchspace.csir.co.za PY - 2001 T1 - Strategies to monitor non-homogeneous atmospheres in sealed off panels in coal mines TI - Strategies to monitor non-homogeneous atmospheres in sealed off panels in coal mines UR - http://hdl.handle.net/10204/1284 ER -