dc.contributor.author |
Smith, S
|
|
dc.contributor.author |
Madzivhandila, P
|
|
dc.contributor.author |
Sewart, R
|
|
dc.contributor.author |
Govender, Ureshnie
|
|
dc.contributor.author |
Becker, H
|
|
dc.contributor.author |
Land, K
|
|
dc.contributor.author |
Roux, P
|
|
dc.date.accessioned |
2017-02-23T10:04:18Z |
|
dc.date.available |
2017-02-23T10:04:18Z |
|
dc.date.issued |
2016-10 |
|
dc.identifier.citation |
Smith, S., Madzivhandila, P., Sewart, R., Govender, U., Becker, H., Land, K. and Roux, P. 2016. Automated microfluidic cartridges for point-of-care cell counting. In: 20th International Conference on Miniaturized Systems for Chemistry and Life Sciences (MicroTAS 2016), 9-13 October 2016 |
en_US |
dc.identifier.uri |
https://www.researchgate.net/publication/309351016_Automated_Microfluidic_Cartridges_For_Point-Of-Care_Cell_Counting
|
|
dc.identifier.uri |
http://hdl.handle.net/10204/8974
|
|
dc.description |
20th International Conference on Miniaturized Systems for Chemistry and Life Sciences (MicroTAS 2016), 9-13 October 2016 |
en_US |
dc.description.abstract |
This work presents microfluidic cartridges for automated blood cell counting towards a point-of-care (POC) full blood count (FBC). Total white blood cell count (WBC) and red blood cell count (RBC) tests were implemented using low-cost, disposable and mass producible microfluidic cartridges with automated sample introduction and processing steps for visual microscopy cell counting to be performed. Results across 10 WBC and 10 RBC cartridges compared well with gold standard FBC results and were within acceptable error ranges. |
en_US |
dc.language.iso |
en |
en_US |
dc.relation.ispartofseries |
Wokflow;17763 |
|
dc.subject |
Microfluidic cartridges |
en_US |
dc.subject |
Point-of-care diagnostics |
en_US |
dc.subject |
Cell counting |
en_US |
dc.title |
Automated microfluidic cartridges for point-of-care cell counting |
en_US |
dc.type |
Conference Presentation |
en_US |
dc.identifier.apacitation |
Smith, S., Madzivhandila, P., Sewart, R., Govender, U., Becker, H., Land, K., & Roux, P. (2016). Automated microfluidic cartridges for point-of-care cell counting. http://hdl.handle.net/10204/8974 |
en_ZA |
dc.identifier.chicagocitation |
Smith, S, P Madzivhandila, R Sewart, Ureshnie Govender, H Becker, K Land, and P Roux. "Automated microfluidic cartridges for point-of-care cell counting." (2016): http://hdl.handle.net/10204/8974 |
en_ZA |
dc.identifier.vancouvercitation |
Smith S, Madzivhandila P, Sewart R, Govender U, Becker H, Land K, et al, Automated microfluidic cartridges for point-of-care cell counting; 2016. http://hdl.handle.net/10204/8974 . |
en_ZA |
dc.identifier.ris |
TY - Conference Presentation
AU - Smith, S
AU - Madzivhandila, P
AU - Sewart, R
AU - Govender, Ureshnie
AU - Becker, H
AU - Land, K
AU - Roux, P
AB - This work presents microfluidic cartridges for automated blood cell counting towards a point-of-care (POC) full blood count (FBC). Total white blood cell count (WBC) and red blood cell count (RBC) tests were implemented using low-cost, disposable and mass producible microfluidic cartridges with automated sample introduction and processing steps for visual microscopy cell counting to be performed. Results across 10 WBC and 10 RBC cartridges compared well with gold standard FBC results and were within acceptable error ranges.
DA - 2016-10
DB - ResearchSpace
DP - CSIR
KW - Microfluidic cartridges
KW - Point-of-care diagnostics
KW - Cell counting
LK - https://researchspace.csir.co.za
PY - 2016
T1 - Automated microfluidic cartridges for point-of-care cell counting
TI - Automated microfluidic cartridges for point-of-care cell counting
UR - http://hdl.handle.net/10204/8974
ER -
|
en_ZA |