ResearchSpace

Blister pouches for effective reagent storage and release for low-cost point-of-care diagnostic applications

Show simple item record

dc.contributor.author Smith, S
dc.contributor.author Sewart, R
dc.contributor.author Land, K
dc.contributor.author Roux, P
dc.contributor.author Gärtner, C
dc.contributor.author Becker, H
dc.date.accessioned 2016-07-11T10:46:54Z
dc.date.available 2016-07-11T10:46:54Z
dc.date.issued 2016-02
dc.identifier.citation Smith, S. Sewart, R. Land, K. Roux, P. Gärtner, C. and Becker, H. 2016. Blister pouches for effective reagent storage and release for low-cost point-of-care diagnostic applications. In: SPIE proceedings 9705, Microfluidics, BioMEMS, and Medical Microsystems XIV, 97050F, San Francisco, California, United States, 13 February 2016 en_US
dc.identifier.uri http://spie.org/Publications/Proceedings/Paper/10.1117/12.2217963
dc.identifier.uri http://hdl.handle.net/10204/8619
dc.description SPIE proceedings 9705, Microfluidics, BioMEMS, and Medical Microsystems XIV, 97050F, San Francisco, California, United States, 13 February 2016 en_US
dc.description.abstract Lab-on-a-chip devices are often applied to point-of-care diagnostic solutions as they are low-cost, compact, disposable, and require only small sample volumes. For such devices, various reagents are required for sample preparation and analysis and, for an integrated solution to be realized, on-chip reagent storage and automated introduction are required. This work describes the implementation and characterization of effective liquid reagent storage and release mechanisms utilizing blister pouches applied to various point-of-care diagnostic device applications. The manufacturing aspects as well as performance parameters are evaluated. en_US
dc.language.iso en en_US
dc.publisher SPIE en_US
dc.relation.ispartofseries Workflow;16794
dc.subject Lab-on-a-chip en_US
dc.subject Point-of-care diagnostics en_US
dc.subject Microfluidics en_US
dc.subject Reagent storage en_US
dc.subject Blister pouches en_US
dc.title Blister pouches for effective reagent storage and release for low-cost point-of-care diagnostic applications en_US
dc.type Conference Presentation en_US
dc.identifier.apacitation Smith, S., Sewart, R., Land, K., Roux, P., Gärtner, C., & Becker, H. (2016). Blister pouches for effective reagent storage and release for low-cost point-of-care diagnostic applications. SPIE. http://hdl.handle.net/10204/8619 en_ZA
dc.identifier.chicagocitation Smith, S, R Sewart, K Land, P Roux, C Gärtner, and H Becker. "Blister pouches for effective reagent storage and release for low-cost point-of-care diagnostic applications." (2016): http://hdl.handle.net/10204/8619 en_ZA
dc.identifier.vancouvercitation Smith S, Sewart R, Land K, Roux P, Gärtner C, Becker H, Blister pouches for effective reagent storage and release for low-cost point-of-care diagnostic applications; SPIE; 2016. http://hdl.handle.net/10204/8619 . en_ZA
dc.identifier.ris TY - Conference Presentation AU - Smith, S AU - Sewart, R AU - Land, K AU - Roux, P AU - Gärtner, C AU - Becker, H AB - Lab-on-a-chip devices are often applied to point-of-care diagnostic solutions as they are low-cost, compact, disposable, and require only small sample volumes. For such devices, various reagents are required for sample preparation and analysis and, for an integrated solution to be realized, on-chip reagent storage and automated introduction are required. This work describes the implementation and characterization of effective liquid reagent storage and release mechanisms utilizing blister pouches applied to various point-of-care diagnostic device applications. The manufacturing aspects as well as performance parameters are evaluated. DA - 2016-02 DB - ResearchSpace DP - CSIR KW - Lab-on-a-chip KW - Point-of-care diagnostics KW - Microfluidics KW - Reagent storage KW - Blister pouches LK - https://researchspace.csir.co.za PY - 2016 T1 - Blister pouches for effective reagent storage and release for low-cost point-of-care diagnostic applications TI - Blister pouches for effective reagent storage and release for low-cost point-of-care diagnostic applications UR - http://hdl.handle.net/10204/8619 ER - en_ZA


Files in this item

This item appears in the following Collection(s)

Show simple item record