ResearchSpace

Wind pressure loading for tall buidings: a case study of Warsaw Trade Tower

Show simple item record

dc.contributor.author Cwik, M
dc.contributor.author Gizejowski, MA
dc.contributor.author Goliger, Adam M
dc.contributor.author Sitek, M
dc.date.accessioned 2013-04-17T10:12:37Z
dc.date.available 2013-04-17T10:12:37Z
dc.date.issued 2012-12
dc.identifier.citation Cwik, M, Gizejowski, M.A, Goliger, A.M and Sitek, M. 2012. Wind pressure loading for tall buidings: a case study of Warsaw Trade Tower. In: Lightweight Structures in Civil Engineering, Warsaw Military University of Technology (WAT), Warsaw, 7 December 2012 en_US
dc.identifier.uri http://hdl.handle.net/10204/6668
dc.description Lightweight Structures in Civil Engineering, Warsaw Military University of Technology (WAT), Warsaw, 7 December 2012 en_US
dc.description.abstract This paper presents an overview of wind-tunnel tests of one of the highest buildings in Poland - Warsaw Trade Tower. The aim of the tests was to evaluate the extreme values of wind pressure over building facade. In the first part, the development of the building model and its surroundings, as well as the testing methods are described. The second part provides a description of the evaluation of the extreme pressure values using Gumbel distribution. Minimum and maximum wind pressure patterns over facade are discussed in the third part. en_US
dc.language.iso en en_US
dc.publisher Warsaw Military University of Technology en_US
dc.relation.ispartofseries Workflow;10101
dc.subject Wind tunnel testing en_US
dc.subject High-rise buildings en_US
dc.subject Wind action en_US
dc.title Wind pressure loading for tall buidings: a case study of Warsaw Trade Tower en_US
dc.type Conference Presentation en_US
dc.identifier.apacitation Cwik, M., Gizejowski, M., Goliger, A. M., & Sitek, M. (2012). Wind pressure loading for tall buidings: a case study of Warsaw Trade Tower. Warsaw Military University of Technology. http://hdl.handle.net/10204/6668 en_ZA
dc.identifier.chicagocitation Cwik, M, MA Gizejowski, Adam M Goliger, and M Sitek. "Wind pressure loading for tall buidings: a case study of Warsaw Trade Tower." (2012): http://hdl.handle.net/10204/6668 en_ZA
dc.identifier.vancouvercitation Cwik M, Gizejowski M, Goliger AM, Sitek M, Wind pressure loading for tall buidings: a case study of Warsaw Trade Tower; Warsaw Military University of Technology; 2012. http://hdl.handle.net/10204/6668 . en_ZA
dc.identifier.ris TY - Conference Presentation AU - Cwik, M AU - Gizejowski, MA AU - Goliger, Adam M AU - Sitek, M AB - This paper presents an overview of wind-tunnel tests of one of the highest buildings in Poland - Warsaw Trade Tower. The aim of the tests was to evaluate the extreme values of wind pressure over building facade. In the first part, the development of the building model and its surroundings, as well as the testing methods are described. The second part provides a description of the evaluation of the extreme pressure values using Gumbel distribution. Minimum and maximum wind pressure patterns over facade are discussed in the third part. DA - 2012-12 DB - ResearchSpace DP - CSIR KW - Wind tunnel testing KW - High-rise buildings KW - Wind action LK - https://researchspace.csir.co.za PY - 2012 T1 - Wind pressure loading for tall buidings: a case study of Warsaw Trade Tower TI - Wind pressure loading for tall buidings: a case study of Warsaw Trade Tower UR - http://hdl.handle.net/10204/6668 ER - en_ZA


Files in this item

This item appears in the following Collection(s)

Show simple item record