dc.contributor.author |
Marullo-Reedtz, G
|
|
dc.contributor.author |
Cerri, R
|
|
dc.contributor.author |
Blanc, I
|
|
dc.contributor.author |
Gunnarsson, O
|
|
dc.contributor.author |
Williams, J
|
|
dc.contributor.author |
Raso, F
|
|
dc.contributor.author |
Kim, KT
|
|
dc.contributor.author |
Frenkel, RB
|
|
dc.contributor.author |
Zhang, XZ
|
|
dc.contributor.author |
Katkov, AS
|
|
dc.contributor.author |
Dziuba, R
|
|
dc.contributor.author |
Parker, M
|
|
dc.contributor.author |
Wood, BM
|
|
dc.contributor.author |
Christian, LA
|
|
dc.contributor.author |
Tarnow, E
|
|
dc.contributor.author |
Mahajan, SK
|
|
dc.contributor.author |
Singh, A
|
|
dc.contributor.author |
Sakamoto, Y
|
|
dc.date.accessioned |
2007-06-08T06:33:21Z |
|
dc.date.available |
2007-06-08T06:33:21Z |
|
dc.date.issued |
2003-04 |
|
dc.identifier.citation |
Marullo-Reedtz, G, et al. 2003. Comparison CCEM-K8 of DC voltage ratio: results. IEEE transactions on instrumentation and measurement, vol. 52 (2), pp 419-423 |
en |
dc.identifier.issn |
0018-9456 |
|
dc.identifier.uri |
http://hdl.handle.net/10204/449
|
|
dc.description |
Copyright: 2003 IEEE |
en |
dc.description.abstract |
This article discusses the outcome of DC voltage ratio comparison CCEM-K8 that was participated by fifteen National Metrology Institutes. The need for a key comparison of DC voltage ratio was recognized by the Comite’ International d’electricite’ et Magnetisme (CCEM) at its 20th meeting in June 1995. Its purpose was to compare the scaling capabilities in DC voltage of the National Metrology Institutes (NMI) up to 1000v. After preliminary studies carried out at IEN [1], a Daltron 4902s voltage divider(s/n20.335) as the traveling standard was adopted to normalize the participants’ results, the calculation of the key comparison reference values and the comparison results were reported for the two mandatory ratios of the comparison, 1000v/10v and 100v/ 10v. More detailed informational and the results for the optional measurement can be found in the comparison final report [3]. |
en |
dc.language.iso |
en |
en |
dc.publisher |
IEEE-INST Electrical Eletronics Engineers INC |
en |
dc.subject |
DC voltage ratios |
en |
dc.subject |
International DC voltage comparisons |
en |
dc.subject |
Key voltage comparisons |
en |
dc.subject |
Voltage dividers |
en |
dc.title |
Comparison CCEM-K8 of DC voltage ratio: results |
en |
dc.type |
Article |
en |
dc.identifier.apacitation |
Marullo-Reedtz, G., Cerri, R., Blanc, I., Gunnarsson, O., Williams, J., Raso, F., ... Sakamoto, Y. (2003). Comparison CCEM-K8 of DC voltage ratio: results. http://hdl.handle.net/10204/449 |
en_ZA |
dc.identifier.chicagocitation |
Marullo-Reedtz, G, R Cerri, I Blanc, O Gunnarsson, J Williams, F Raso, KT Kim, et al "Comparison CCEM-K8 of DC voltage ratio: results." (2003) http://hdl.handle.net/10204/449 |
en_ZA |
dc.identifier.vancouvercitation |
Marullo-Reedtz G, Cerri R, Blanc I, Gunnarsson O, Williams J, Raso F, et al. Comparison CCEM-K8 of DC voltage ratio: results. 2003; http://hdl.handle.net/10204/449. |
en_ZA |
dc.identifier.ris |
TY - Article
AU - Marullo-Reedtz, G
AU - Cerri, R
AU - Blanc, I
AU - Gunnarsson, O
AU - Williams, J
AU - Raso, F
AU - Kim, KT
AU - Frenkel, RB
AU - Zhang, XZ
AU - Katkov, AS
AU - Dziuba, R
AU - Parker, M
AU - Wood, BM
AU - Christian, LA
AU - Tarnow, E
AU - Mahajan, SK
AU - Singh, A
AU - Sakamoto, Y
AB - This article discusses the outcome of DC voltage ratio comparison CCEM-K8 that was participated by fifteen National Metrology Institutes. The need for a key comparison of DC voltage ratio was recognized by the Comite’ International d’electricite’ et Magnetisme (CCEM) at its 20th meeting in June 1995. Its purpose was to compare the scaling capabilities in DC voltage of the National Metrology Institutes (NMI) up to 1000v. After preliminary studies carried out at IEN [1], a Daltron 4902s voltage divider(s/n20.335) as the traveling standard was adopted to normalize the participants’ results, the calculation of the key comparison reference values and the comparison results were reported for the two mandatory ratios of the comparison, 1000v/10v and 100v/ 10v. More detailed informational and the results for the optional measurement can be found in the comparison final report [3].
DA - 2003-04
DB - ResearchSpace
DP - CSIR
KW - DC voltage ratios
KW - International DC voltage comparisons
KW - Key voltage comparisons
KW - Voltage dividers
LK - https://researchspace.csir.co.za
PY - 2003
SM - 0018-9456
T1 - Comparison CCEM-K8 of DC voltage ratio: results
TI - Comparison CCEM-K8 of DC voltage ratio: results
UR - http://hdl.handle.net/10204/449
ER -
|
en_ZA |