dc.contributor.author |
O'Brien, TM
|
|
dc.date.accessioned |
2008-01-22T09:35:43Z |
|
dc.date.available |
2008-01-22T09:35:43Z |
|
dc.date.issued |
2004-03 |
|
dc.identifier.citation |
O’Brien, TM. 2004. Investigation into the effects of steel wire rope specimen length on breaking force. Safety in Mines Research Advisory Committee, GAP 836, March 2004, pp 63 |
en |
dc.identifier.uri |
http://hdl.handle.net/10204/1889
|
|
dc.description.abstract |
This report covers work conducted to evaluate the effects of specimen length on the
breaking force, in an attempt to validate or refine the discard criteria of SABS 0293: 1996. Inter alia, this included an examination of the postulation of van Zyl (2000). The methodology employed was to test different length of triangular strand and non-spin rope to destruction, and to evaluate these results against SABS 0293:1996. For each rope construction, specimens were prepared both with and without cut wires, giving a total of some 26 triangular strand and five non-spin samples. Unfortunately, anomalous behaviour of the non-spin rope led to the discontinuation of these tests in favour of a greater number of triangular strand rope specimens |
en |
dc.language.iso |
en |
en |
dc.subject |
SIMRAC |
en |
dc.subject |
GAP 836 |
en |
dc.subject |
Steel wire rope |
en |
dc.subject |
Specimen length |
en |
dc.subject |
Investigation |
en |
dc.subject |
Triangular strand |
en |
dc.title |
Investigation into the effects of steel wire rope specimen length on breaking force |
en |
dc.type |
Conference Presentation |
en |
dc.identifier.apacitation |
O'Brien, T. (2004). Investigation into the effects of steel wire rope specimen length on breaking force. http://hdl.handle.net/10204/1889 |
en_ZA |
dc.identifier.chicagocitation |
O'Brien, TM. "Investigation into the effects of steel wire rope specimen length on breaking force." (2004): http://hdl.handle.net/10204/1889 |
en_ZA |
dc.identifier.vancouvercitation |
O'Brien T, Investigation into the effects of steel wire rope specimen length on breaking force; 2004. http://hdl.handle.net/10204/1889 . |
en_ZA |
dc.identifier.ris |
TY - Conference Presentation
AU - O'Brien, TM
AB - This report covers work conducted to evaluate the effects of specimen length on the
breaking force, in an attempt to validate or refine the discard criteria of SABS 0293: 1996. Inter alia, this included an examination of the postulation of van Zyl (2000). The methodology employed was to test different length of triangular strand and non-spin rope to destruction, and to evaluate these results against SABS 0293:1996. For each rope construction, specimens were prepared both with and without cut wires, giving a total of some 26 triangular strand and five non-spin samples. Unfortunately, anomalous behaviour of the non-spin rope led to the discontinuation of these tests in favour of a greater number of triangular strand rope specimens
DA - 2004-03
DB - ResearchSpace
DP - CSIR
KW - SIMRAC
KW - GAP 836
KW - Steel wire rope
KW - Specimen length
KW - Investigation
KW - Triangular strand
LK - https://researchspace.csir.co.za
PY - 2004
T1 - Investigation into the effects of steel wire rope specimen length on breaking force
TI - Investigation into the effects of steel wire rope specimen length on breaking force
UR - http://hdl.handle.net/10204/1889
ER -
|