ResearchSpace

Mechanical miner environmental control: evaluation of ventilation and dust control systems in a ventilation simulation tunnel.

Show simple item record

dc.contributor.author Du Plessis, JJL
dc.contributor.author Belle, BK
dc.contributor.author Vassard, PS
dc.date.accessioned 2007-11-08T13:59:49Z
dc.date.available 2007-11-08T13:59:49Z
dc.date.issued 1999-01
dc.identifier.citation Du Plessis, JJL, Belle, BK and Vassard, PS. 1999. Mechanical miner environmental control: evaluation of ventilation and dust control systems in a ventilation simulation tunnel. Safety in Mines Research Advisory Committee, COL 518, January, 1999, pp 1-138 en
dc.identifier.uri http://hdl.handle.net/10204/1460
dc.description.abstract The primary objective of this report was to control the environment to ensure that dust and methane levels were within the regulating requirements. The mining industry, through the SIMRAC process, assigned the CSIR-Miningtek to test and evaluate ventilation systems to ensure compliance with the new dust standard and the existing methane standard. en
dc.language.iso en en
dc.subject SIMRAC en
dc.subject COL 518 en
dc.subject Dust control systems en
dc.subject Mechanical miner environmental controls en
dc.subject Ventilation simulation tunnel en
dc.title Mechanical miner environmental control: evaluation of ventilation and dust control systems in a ventilation simulation tunnel. en
dc.type Conference Presentation en
dc.identifier.apacitation Du Plessis, J., Belle, B., & Vassard, P. (1999). Mechanical miner environmental control: evaluation of ventilation and dust control systems in a ventilation simulation tunnel. http://hdl.handle.net/10204/1460 en_ZA
dc.identifier.chicagocitation Du Plessis, JJL, BK Belle, and PS Vassard. "Mechanical miner environmental control: evaluation of ventilation and dust control systems in a ventilation simulation tunnel." (1999): http://hdl.handle.net/10204/1460 en_ZA
dc.identifier.vancouvercitation Du Plessis J, Belle B, Vassard P, Mechanical miner environmental control: evaluation of ventilation and dust control systems in a ventilation simulation tunnel; 1999. http://hdl.handle.net/10204/1460 . en_ZA
dc.identifier.ris TY - Conference Presentation AU - Du Plessis, JJL AU - Belle, BK AU - Vassard, PS AB - The primary objective of this report was to control the environment to ensure that dust and methane levels were within the regulating requirements. The mining industry, through the SIMRAC process, assigned the CSIR-Miningtek to test and evaluate ventilation systems to ensure compliance with the new dust standard and the existing methane standard. DA - 1999-01 DB - ResearchSpace DP - CSIR KW - SIMRAC KW - COL 518 KW - Dust control systems KW - Mechanical miner environmental controls KW - Ventilation simulation tunnel LK - https://researchspace.csir.co.za PY - 1999 T1 - Mechanical miner environmental control: evaluation of ventilation and dust control systems in a ventilation simulation tunnel TI - Mechanical miner environmental control: evaluation of ventilation and dust control systems in a ventilation simulation tunnel UR - http://hdl.handle.net/10204/1460 ER - en_ZA