dc.contributor.author |
Erasmus, TC
|
|
dc.date.accessioned |
2023-07-04T06:08:15Z |
|
dc.date.available |
2023-07-04T06:08:15Z |
|
dc.date.issued |
1962 |
|
dc.identifier.citation |
Erasmus, T. 1962. <i>Experiments conducted to determine the reproduceability of washing tests and the significance of probable error determinations</i>. http://hdl.handle.net/10204/12850 . |
en_ZA |
dc.identifier.uri |
http://hdl.handle.net/10204/12850
|
|
dc.description.abstract |
The raw coal brought to the plant was reduced to minus three inches. The minus coal was passed over screens to eliminate minus 1/4 inch fines and -3 inch +1/4 inch coal was stored in service bunkers in the pilot plant building. |
en_US |
dc.format |
Fulltext |
en_US |
dc.language.iso |
en |
en_US |
dc.subject |
Shallow bath |
en_US |
dc.subject |
Drewboy washer |
en_US |
dc.subject |
Magnetite |
en_US |
dc.subject |
Separating vessel |
en_US |
dc.title |
Experiments conducted to determine the reproduceability of washing tests and the significance of probable error determinations |
en_US |
dc.type |
Report |
en_US |
dc.description.pages |
13pp |
en_US |
dc.description.reportnumber |
TM 19/1962 |
en_US |
dc.identifier.apacitation |
Erasmus, T. (1962). <i>Experiments conducted to determine the reproduceability of washing tests and the significance of probable error determinations</i> Retrieved from http://hdl.handle.net/10204/12850 |
en_ZA |
dc.identifier.chicagocitation |
Erasmus, TC <i>Experiments conducted to determine the reproduceability of washing tests and the significance of probable error determinations.</i> 1962. http://hdl.handle.net/10204/12850 |
en_ZA |
dc.identifier.vancouvercitation |
Erasmus T. Experiments conducted to determine the reproduceability of washing tests and the significance of probable error determinations. 1962 [cited yyyy month dd]. Available from: http://hdl.handle.net/10204/12850 |
en_ZA |
dc.identifier.ris |
TY - Report
AU - Erasmus, TC
AB - The raw coal brought to the plant was reduced to minus three inches. The minus coal was passed over screens to eliminate minus 1/4 inch fines and -3 inch +1/4 inch coal was stored in service bunkers in the pilot plant building.
DA - 1962
DB - ResearchSpace
DP - CSIR
KW - Shallow bath
KW - Drewboy washer
KW - Magnetite
KW - Separating vessel
LK - https://researchspace.csir.co.za
PY - 1962
T1 - Experiments conducted to determine the reproduceability of washing tests and the significance of probable error determinations
TI - Experiments conducted to determine the reproduceability of washing tests and the significance of probable error determinations
UR - http://hdl.handle.net/10204/12850
ER -
|
en_ZA |
dc.identifier.worklist |
n/a |
en_US |